- 比负荷系数法--选用风冷热泵机组的新方法[2004-11-16] 本文就空调工程设计中,如何选用风冷热泵机组这个问题,提出了一个新的概念:比负荷系数。阐述了运用比负荷系数法选用风冷热泵机组的理论依据及设计步骤,使设计人员在选用风冷热泵机组时,有了科学的实用方法。...阅读全文>>
- RESIDENTIAL ENERGY CONSUMPTION IN CHINA: A LITERAT[2004-11-16] Over the last two decades in China, the mushrooming residential energy consumption has been developing an enormous stress on the national energy system and the global environment. Diversities of researches have been carried out to study the pertinent issues. This pa...阅读全文>>
- 2000年第6期[2004-11-16] 中国即将加入世界贸易组织。暖通空调业是国内开放较早的行业之一,加入WTO机遇大于挑战。分别从暖通空调的设备制造业、设计单位以及能源工业的角度,分析了企业如何抓住机遇、迎接挑战。就暖通空调企业如何应对网络经济的潮流提出了个人的观点和建议。...阅读全文>>
- 半导体制冷及其应用[2004-11-16] 阅读全文>>
- 蓄冷式空调工程的设计及其技术经济分析[2004-11-16] 本文认为我国目前发展蓄冷空调的时机已经来到,技术已近成熟,但应以发展冰蓄冷先导,带动蓄冷技术健康发展阅读全文>>
- MODELING OF A COOLING CEILING USING STEADY -STATE[2004-11-16] The paper presents a new approach for steady-state analysis used to model the heat transfer from a cooling ceiling system. The work is aimed at giving a better insight to crucial parameters of such a model as the contact thermal resistance, and the fin effectiveness...阅读全文>>
- 2000年第5期[2004-11-16] 阐述了系统特征图的原理、方法及作用,指出只要形成系统、能用网络图表述的,均可用特征图表示,如供水系统、供暖系统。简要介绍了特征图在风道计算中的应用,认为特征图不仅适用于矿井通风,而且可用于建筑物的通风空调系统。...阅读全文>>
- 住宅采暖计量收费方法的探讨[2004-11-16] 阅读全文>>
- 2003年第二期[2004-11-16] 利用价值工程的有关原理建立了新型建筑给水无聊管材评价模型,并对模型进行了分析与评价,通过工程实例严整了该模型的有效性。运用该模型对这些塑料管材进行了分析评价,为建筑给水工程优化设计提供依据,为新型建筑给水塑料管材发展指出了方向。
...阅读全文>>
- 2000年第3期[2004-11-16] 调查了106人对各种吹风方式的评价。讨论了自然风与机械风的湍流强度、速度分布、频谱参数的不同。探讨了这些差异产生的原因及其与吹风舒适性的关系。阅读全文>>
- 1997年第一期[2004-11-16] 阅读全文>>
- THE THERMAL COMFORT ANALYSIS UNDER DIFFERENT AIR D[2004-11-16] The evaluation of various ventilation strategies for optimal thermal comfort design in terms of predicted mean vote index was investigated. The major parameter is the inlet/outlet diffuser's locations in the occupied region. The location effects of the inlet and out...阅读全文>>
- 风冷热泵和水源热泵空调系统的设计和应用[2004-11-16] 阅读全文>>
- DEMAND CONTROL FOR FRESH AIR VENTILATION IN COMMER[2004-11-16] Source control and adequate supply of outdoor air are two strategies that used to achieve good Indoor Air Quality (IAQ). The design fresh air supply flowrate depends on the peak occupancy. In an office with varying occupancy or large infiltration, it offers an oppo...阅读全文>>
- 2000年第3期[2004-11-16] 通过对医院环境可采用的净化方式的对比,认为目前我国医院宜采用局部净化系统控制其环境质量。理论计算及现场测试数据表明所研制的空气净化器满足医院消毒卫生标准,是经济有效的。阅读全文>>
- 1999年第11期[2004-11-16] 介绍地下汽车库的械机通风和排烟风量的确定方法,提供了一种比较典型的通风与排烟系统的设置方式,阐述了两者之间的关系,提出做好设计的关键在于合理、准确的划分防烟分区。阅读全文>>
- ENERGY SAVINGS IN ICE STORAGE SYSTEM BY DESIGN[2004-11-16] Three ways to improve ice storage of chiller and ice bank in series are analyzed using a system simulation program known as TSTORSP:(1)secondary pump; (2) self-regulated valve; (3) variable speed pump. It is shown that a lot of energy canbe saved by using secondary ...阅读全文>>
- 复杂热水供热管网计算机解算[2004-11-16] 本文提出了用最小树原理的加边法自动选择独立回路,用Scott-hinsley试算法迭代解算复杂热水供热管网的数学模型。阐述了解算过程中对诸如随水温变化的热水密度计算、热压计算、水泵特性曲线模拟、管道阻力特性数计算等具体工程问题的处理方法。依此编制的解算程序操作简便、可靠。最后给出...阅读全文>>
- 2000年第6期[2004-11-16] 通过对多个空调系统的调查和分析,分析总结了在冷冻站和空调系统内发现的若干常见问题,这些问题都会导致空调系统运行故障,应引起空调设计和运行人员的注意阅读全文>>
- 采暖系统自适应控制运行方案研究[2004-11-16] 目前,国内先后出现了多种适合热计量的供热采暖系统运行方案,其中多数为垂直单管带跨越管、两通恒温阀系统。由于系统特性,运行方式多采用质调节,循环水泵电耗大。本论文提出了一种适合该系统的质量并调方案,可节约水泵电耗。另外,由于常规采暖系统在一定时期内还会大量存在,而现有的质量并调方案...阅读全文>>
地址:中国·郑州金水区 热线:13007606916,13223029089/ 0371-60957609