Assesment of relationship between measured, predicted health and energy consumption in 12 Dutch offi

2012年02月28 00:00:00 来源:中国空调制冷网
According to this research, the BSI varied widely between 0.2 and 1.9. This means

no serious problems with the Sick Building Syndrome could be expected. The BCI

(average summer/ winter situation) lies between 2.4 and 3.8, which is reasonably

good. The energy consumption varied strongly between 586 and 2 873 MJ/m2 gross

floor area, while the average energy consumption of the buildings in this research

was 35% higher than the EU average. The BSIp showed a strong relation to the

measured BSI for the investigated buildings; the Correlation Coefficient (Kendall’s

tau) is 0.77 and P<0.01.