- THERAL COMFORT CONTROL STUDY BY CFD[2004-11-16] This article studies the thermal comfort control strategy of an indoor environment by computational fluid dynamics (CFD) software. It intends to show the capabilities of the CFD in modeling and predicting the room air dynamics. A room model with an exposed wall has ...阅读全文>>
- 2000年第4期[2004-11-16] 介绍和分析了以玻璃幕墙上的轻型钢结构作为输水管路和放热体的组合供暖系统的形式、特点,并给出了计算例题。阅读全文>>
- A STMULATION TOOL FOR THE MODELLING OF WATER AND A[2004-11-16] In this paper a simulation tool is presented which can be used for the modeling of air and water distribution networks. Based on basic approaches for network resistances and topology a model for the calculation of the pressure and flow distribution in any kind of ne...阅读全文>>
- STUDY ON FAULT DETECTION AND DIAGNOSIS OF HVAC SYS[2004-11-16] When some faults take place in HVAC system changing pattern of the state variables of using some statistical analysis, Fourier Trans form, Cluster analysis and variable selection to achieve optimal fault detection parameter. and using recognizing patterns with Mahan...阅读全文>>
- 1997年第1期[2004-11-16] 阅读全文>>
- 2000年第4期[2004-11-16] 阅读全文>>
- 上海儿童医学中心冰蓄冷技术的运用[2004-11-16] 阅读全文>>
- 1999年第11期[2004-11-16] 针对目前集中供热的收费方式,分析了其存在的各种问题。并提出了几利可行的其它收费方式。建议集中供热设计采暖热负荷收费。阅读全文>>
- 荷电水雾除尘的实验研究[2004-11-16] 选择适于水雾荷电的单相雾化喷咀,用相对安全,简便的感应荷电法对雾滴荷电规律和水雾除尘效果做了系统测试。分析了该方式下系统的结构、运行、电气等参数对雾滴荷电程度的影响,并对其实际应用给出了建议。...阅读全文>>
- 润滑油对混合工质空调压缩机性能的影响[2004-11-16] 本文对替代工质R32/R134a与聚酯类合成润滑油(POE)的相容性进行了研究;对四种不同的POE润滑油与R32/R134a进行了相容性试验;试验结果为进一步选择或改进与R32/R134a相适应的润滑油提供了依据阅读全文>>
- 全年空调负荷与运行方案实用分析方法 清华大学热能工程系[2004-11-16] 空调负荷的精确求解,不可避免地遇到热辐射的分配比例问题,本文结合空调房间的下部送风,针对不同结构的房间。通过对辐射扰量在围护结构内表面不同分配比例的条件下进行计算与分析后得出,以前常规的按面积均分辐射热量或别的近似处理方法,将会给房间负荷的计算造成较大的误差,正确的方法应该是按...阅读全文>>
- EXPERIMENTAL RESEARCH ON NATURAL CONVECTION HEAT T[2004-11-16] Based on finned-tube room radiators , experimentally showed that for two-tube vertical arrangement, heat transfer coefficient of the lower tube is badly degraded by the preheating from lower tubes. Maximum total heat transfer at upper tubes is badly degraded by the...阅读全文>>
- 2000年第6期[2004-11-16] 提出了近几年福建省暖通设计存在的若干问题,如设备选择及水系统设计不当,对空气品质重视不够,规范贯彻不力,等。分析了产生这些问题的原因,并探讨了解决的对策。阅读全文>>
- 2000年第一期[2004-11-16] 阅读全文>>
- 商场的新风冷负荷特点及一种将其有效利用的空调系统[2004-11-16] 本文针对商场建筑,分析了新风负荷的特点,在上述空调系统的基础上,提出一种新的空调系统形式,可适当地减少能耗并提高室内空气品质,供设计者参考。阅读全文>>
- 2003年第二期[2004-11-16] 分析了定压供水系统变频泵功耗和泵流量的一次方程正比,用系统思考的方法指出“一变多定”配置泵群应用的局限,提出高性能离心泵群实用变频控制方案。阅读全文>>
- OPTIMIZATION DESIGNS AND DYNAMIC MULATIONS ABOUT T[2004-11-16] This paper mainly researches the dynamic traits of the temperature regulating dehumidifiers subsystems such as compressor, cooler (air, water of air-water), throttle valve and vaporizer. As a result, the system of the temperature regulating dehumidifiers obtains the...阅读全文>>
- 浅谈民用建筑空调设计围护物冷负荷的简易计算[2004-11-16] 本论文原文篇幅较大,在此由于篇幅有限,作者仅简要说明编制冷负荷速算表的必要性,并通过编制福建地区围护物冷负荷速算表说明其可行性、规律性和实用性,并建议全国亦编制出本地区的速算表,以减轻繁重的围护冷负荷计算工作量。...阅读全文>>
- ENERGY CONSERVATION AND RETROFITTING POTENTIAL IN[2004-11-16] This paper concludes the problems on operation and energy consumption of air-conditioning systems in emporium buildings on the basis of investigation and surveying materials, analyzed the causes of these problems, presents proposals on design and operation methods o...阅读全文>>
- 2000年第3期[2004-11-16] 探讨了面向方案的概念在开发锅炉房汽水系统CAD软件中的具体应用,其中包括开放的设备数据库、三维设计环境、设计知识的组织和管理等,从而形成了一套完整的CAD软件的开发与实现模式。阅读全文>>